Return to archive
EN · Issue 4 · 2024

AUTOMATED DETECTION OF TISSUE DENSITY DECREASE IN ACUTE ISCHEMIC STROKE USING NON-CONTRAST CT IMAGES AND DEEP NEURAL NETWORK MODELS IN THE CEREBRA SYSTEM

Abstract

Introduction. Acute ischemic stroke remains one of the leading causes of disability and mortality worldwide. Non-contrast computed tomography (NCCT) is the standard primary imaging method, but early ischemic changes (“subtle” tissue density reduction) may be difficult to detect visually. The goal of this study was to develop and evaluate an automated system for detecting regions of reduced density in CT images, based on deep neural network models, and integrated into the «Cerebra» platform. Materials and Methods. The study included 246 patients (127 males and 119 females) with a confirmed diagnosis of acute ischemic stroke. The mean age for males was 58.96 ± 8 years, for females—62.15 ± 8 years. All CT scans were performed on multislice scanners (Fujifilm, GE, Hitachi, Siemens, UIH) using standard protocols. Cascading U-Net-based models (in particular, with an EfficientNet B6 encoder), trained on annotated data verified by three independent radiologists, were used for automatic segmentation of areas with reduced density. Performance was evaluated using Accuracy, Precision, Recall, F1-Score, and Cohen’s Kappa. Results. During 2022–2024, a stepwise improvement in accuracy was observed. In 2024, the Accuracy reached 92.3%, F1-Score was 96.0%, Recall 92.3%, and Precision reached 100%. In 2023, Cohen’s Kappa was 0.80, indicating high agreement with expert assessments. Analysis on different CT scanner models showed the algorithm maintained high reproducibility (F1- Score from 88.8% to 100%) under varying technical conditions. Discussion. These findings confirm that the combined use of image normalization (MNI space), cascading deep neural networks, and consensus annotation by three experts enhances early detection of ischemic changes. Improvements over the years were associated with expansion of the training dataset and regular updating of the model architecture. The “Cerebra” system has demonstrated versatility due to stable results on scanners from different manufacturers. Conclusion. The developed automated system for detecting reduced tissue density can significantly improve diagnostic accuracy in acute ischemic stroke and reduce decision-making time. Further dataset expansion and multicenter validation will enable this solution to be scaled up for widespread clinical use.

Keywords

ischemic strokenon-contrast CTtissue density decreasedeep learningU- NetCerebraautomated detectionearly diagnosis
How to cite
M. SAIFULLAKYZY ¹, ², A.S.ZHUSSUPOVA ¹, ³, E.K.DYUSSEMBEKOV ⁴, ⁵, E.T. MAKHAMBETOV ⁶, R.M. KASTEY ⁵, Zh.B. DYUSSEMBAEVA ⁵, Zh.N. SAGIMBAYEV ¹, M.K. UMURZAKOVA ¹, I.R. FAKHRADIYEV ⁴. AUTOMATED DETECTION OF TISSUE DENSITY DECREASE IN ACUTE ISCHEMIC STROKE USING NON-CONTRAST CT IMAGES AND DEEP NEURAL NETWORK MODELS IN THE CEREBRA SYSTEM. Vestnik KazNMU. 2024; 71(4). doi: 10.53065/kaznmu.2024.71.4.009